Menara Axiata — Acoustic Performance Audit
Field acoustic testing across multiple spaces, assessed against defined criteria and reported with engineering recommendations.
Sound level meter and omnidirectional source positioned in a treated meeting room during field testing.
What happened, in order
-
Client problem
A multi-tenant office fit-out needed its acoustic performance confirmed against defined criteria rather than assumed from the specification.
-
Novico scope
An acoustic performance audit across multiple spaces: partition sound insulation, reverberation and background noise criterion assessment.
-
Measurement / engineering approach
Field measurement under documented conditions following ISO 16283-1 for insulation and ISO 3382-2 for reverberation, with each space measured in its as-built state.
-
Recommendation or implementation
A pass or fail evaluation recorded per space, with engineering recommendations issued for the spaces that did not meet the applicable criteria.
-
Verified outcome
Measured results were compared directly against the agreed criteria. No performance figures, client statements or post-remedial results are published for this project.
What the audit covered?
Novico carried out an acoustic performance audit across multiple spaces. The work covered partition sound insulation, reverberation and background noise criterion assessment, with each space evaluated against the applicable criteria.
The output was a pass or fail evaluation per space together with engineering recommendations addressing the findings.
Partition sound insulation measurement between selected spaces
Reverberation assessment in the spaces concerned
Background noise criterion assessment
Pass / fail evaluation against the applicable criteria
Engineering recommendations based on the findings
PROJECT FACTS
- SERVICE
- Acoustic consultancy & measurement
- SCOPE
- Multi-space acoustic performance audit
- STANDARDS
- ISO 16283-1, ISO 3382-2
- ASSESSMENT
- Pass / fail against criteria
Only the facts supplied for publication are listed here. No performance results, client statements or outcomes are claimed beyond the scope described.
How the audit was structured?
-
01
Criteria agreed
The spaces to be tested and the criteria each would be judged against were defined before measurement.
-
02
Field measurement
Insulation, reverberation and background noise measured on site under documented conditions.
-
03
Evaluation
Measured results compared against the criteria, with pass or fail recorded per space.
-
04
Recommendations
Engineering recommendations issued to address the spaces that did not meet the criteria.
Where to next